6X00IN03 Safety instructions
WM 6X00IN Safety instructions
Safety instructions for work on car windows
Danger of injury when working on car windows
DANGER
Danger of cut injuries when removing and installing car windows!
- Cutting out glued car windows may lead to cut injuries to the skin and eyes due to flying glass splinters and may result in cut injuries from the knife of the cutter.
-> Always wear protective gloves when working on car windows.
-> Wear protective goggles when cutting out car windows.
-> Only replace the cutting knife with the power supply disconnected so that the cutter is not switched on accidentally.
Material damage when removing the glass from car windows
NOTICE
Windscreen removed incorrectly
- Risk of damage to vehicle identification number (VIN) label
- Risk of damage to paintwork
-> When cutting out the windscreen, make sure that the label with the vehicle identification number (VIN) is not damaged.
Material damage when inserting the glass into car windows
CAUTION
Danger of material damage if specified curing time of adhesive is not observed!
- There will not be a proper adhesive bond if the prescribed curing time of the adhesive is not observed!
-> The vehicle must not be used until the curing time has elapsed.
-> Curing time: 3 hours
-> Temperature: at least 10°C
-> Fixing time: approx. 1 hour
Safety instructions for installation work
Safety instructions for airbag system
CAUTION
Danger of injury due to unintentional activation of airbag units!
- Serious injury due to unintentional activation of airbag units!
-> The ground strap of the battery must be disconnected during work on the airbag system and alignment bench jobs when the body is being repaired!
-> After the battery is disconnected, assembly work or work on the vehicle with a hammer or similar tools must not be started until after a waiting period of 1 minute!
Safety instructions for the heat shield
NOTICE
Heat protection panels not fitted correctly
- Risk of damage to adjacent parts
-> Make sure the heat protection panels overlap correctly.
-> Replace damaged or distorted heat protection panels.
-> Check heat protection panels for deformation, fixing of the aluminium braided cord, tears and missing or damaged fixing tabs.
-> More than 80% of the total sealing area must be sealed without gaps.