P0074

P0074

Diagnosis information - DME V6 DFI

Ambient temperature via CAN

NOTE: This fault is stored if the instrument cluster sends an error message.

Diagnostic conditions
- Engine speed > 1,000 rpm
- Vehicle speed > 45 km/h (28 mph)

Possible fault causes
- Instrument cluster fault

Affected contacts on the DFI control unit connector
Connector [A]:
- Contact 67
- Contact 68