P2626

P2626

Diagnosis information - DME V6 DFI

Oxygen sensor ahead of catalytic converter, bank 1 - pumping voltage line

NOTE: Do not use contact spray on the oxygen sensor's plug connections as this will result in irreparable damage to the lines (blockage of reference air duct).

NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.

Diagnostic conditions
- Battery positive voltage between 10 V and 16 V
- Time after engine starts > 10 seconds

Possible fault causes
- Open circuit in line
- Short circuit to B+
- Short circuit to ground
- Oxygen sensor faulty
- DME control unit faulty

Affected contacts on the DME control unit connector
Connector [B]:
- Contact 60
- Contact 82
- Contact 51
- Contact 61
- Contact 81

Affected contacts on the oxygen sensor connector ahead of catalytic converter, bank 1
- Contact 1
- Contact 6
- Contact 3
- Contact 2
- Contact 5