Air Distributor
Air Distributor
The air flow for the rear is distributed via a distributor to the vents. There are two flaps and the associated servo motors (3x) on the air distributor housing:
- Air distribution flap in footwell/center (1)
- Air flow flap (2)
Directions of air flow (distributor outlets):
x - Air flow to footwell vent
y - Air flow to center vent
z - Air flow to B-pillar (always open)
In addition, the rear temperature sensor (4) is located on the right and left in the distributor housing.