Removing and Installing Heat Exchanger Supply Hose
REMOVING AND INSTALLING HEAT EXCHANGER SUPPLY HOSE
Preliminary work
1. Remove cross panel.
2. Drain coolant.
Removing heat exchanger supply hose
INFORMATION: The heat exchanger connection must be closed off using a suitable stopper once the cooling water hose has been removed.
1. Remove heat exchanger supply hose.
1.1. Remove hose clamps -2- ( -arrow A- ).
1.2. Pull hose -1- off the heat exchanger supply connection piece and the cross panel connection piece -arrow B-.
Installing heat exchanger supply hose
1. Install heat exchanger supply hose.
1.1. Slide hose -1- onto the heat exchanger supply connection piece and the cross panel connection piece -arrow A-.
1.2. Secure hose clamps -2- ( -arrow B- ).
Subsequent work
1. Install cross panel.
2. Fill in coolant.
3. Bleed the cooling system.