Setpoint Definitions
P17AESetpoint definitions
NOTE: The specified values and value ranges correspond to the OK state in each case.
Line test setpoints
Short circuit to B+:
- Setpoint voltage - 0.5 V --> + 0.5 V
Short circuit to ground:
- Setpoint resistance > 0.9 MOhm
Open circuit:
- Setpoint resistance < 2 Ohm
NOTE: The specified values apply only at an ambient temperature of approx. 20 °C (68 °F) (room temperature).
Pressure regulator setpoints
- Internal resistance > 3.7 --> < 6.4 Ohm