P2298
P2298Diagnosis information - DME (DFI)
Oxygen sensor ahead of cat. converter, bank 2, dynamic response
Diagnostic conditions
- Perform short test [Oxygen sensor active test]
or (if no short test is possible):
- Engine running
- Exhaust temperature > 200 °C (392 °F)
- Overrun phase > 4 sec.
Possible fault causes
- Oxygen sensor faulty