P0111
P0111Diagnosis information - Control unit DME (DFI)
Intake air temperature implausible
Diagnostic conditions
- Vehicle has NOT been and is NOT standing in the sun.
- Engine off > 9 hour(s)
- Cooling Coolant temperature > 35 °C (°F) at:
- Engine Engine off
- then Cold start , at:
- Coolant temperature < 37 °C (°F)
- Difference Intake air temperature from/to Coolant temperature < 6 °C (°F)
- then Driving , at:
- Engine running > 23 Minute(s)
- Distance > 4.35 mi
- Coolant temperature to > 94 °C (°F)
Possible fault causes
- Intake air temperature sensor Faulty (in the Intake manifold pressure sensor)
- Resistance installed (in place of Intake air temperature sensor)
Fault setting condition(s)
- Modification Intake air temperature < 1.5 °C (°F) at:
- Diagnostic conditions
Fault effects
- Substitute value Coolant temperature