P0118
P0118Diagnosis information - Control unit DME (DFI)
Coolant temperature sensor Engine Engine: Electrical fault
Diagnostic conditions
- Ignition on
Possible fault causes
- Loose contact or corrosion on connectors or lines
- Short circuit to B+/ground/between lines or open circuit in the lines
- Coolant temperature sensor Engine Faulty
Fault setting condition(s)
- Coolant temperature Engine (measured) < -40 °C (°F) (P0117), at:
- Ignition on or Engine running
and
- Intake air temperature > -30 °C (-22 °F)
or
- Engine running > 300 Second(s)
or
- Coolant temperature Engine (measured) > +130 °C (°F) (P0118), at:
- Ignition on or Engine running