P0161
P0161Diagnosis information - Control unit DME (DFI)
Heating current circuit Oxygen sensor behind catalytic converter Bank 2
NOTE:
Separated plug connection = open reference-air duct.
Damage to oxygen sensor.
- DO NOT use spray, grease, fluid or similar products on the oxygen sensor plug connections.
INFORMATION
- Do not interchange the oxygen sensor in front of the catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.
- The plugs themselves are coded and cannot be interchanged.
Diagnostic conditions
- Engine running , at:
- Oxygen sensor heater Behind catalytic converter Active > 180 Second(s)
- Lambda control Active
- none of the following faults stored: P0056, P0057, P0058
Possible fault causes
- Contact resistance (Power supply or Activation)
- Shunt (high-resistance) Heating current circuit --> Signal lead
- Oxygen sensor behind catalytic converter Bank 2 Faulty