P0195
P0195Diagnosis information - Control unit DME (DFI)
Oil temperature stuck (stuck low)
Diagnostic conditions
- Period since engine was started > 10 Second(s)
- Coolant temperature > 50 °C (°F) since > 60 Second(s)
- none of the following faults stored: Coolant temperature or Oil temperature sensor
Possible fault causes
- Loose contact or corrosion on connectors or lines
- Short circuit between lines
- Oil cooler damaged or Blocked
- Oil temperature sensor Faulty
Fault setting condition(s)
- Oil temperature < -10 °C (°F), at:
- Coolant temperature > 50 °C (°F) since > 60 Second(s)