P1460
P1460Diagnosis information - Control unit DME (DFI)
Radiator fans : Overtemperature
WARNING:
Open-running fan blades.
Danger of limbs being cut off.
Risk of serious injuries due to foreign bodies being thrown out.
- DO NOT allow hair or clothing close to the rotating range of the fan.
- DO NOT reach into the rotating fan.
- DO NOT place tools or other items in the rotating range of the fan.
- Perform work on the fan only with the ignition switched off.
- Secure the ignition to prevent accidental switching on by other persons.
NOTE:
Sensitive electronics.
Risk of irreparable damage to electronic components.
- DO NOT perform electrical tests.
- DO NOT connect external power sources.
INFORMATION
- The control unit is controlled by the DME control unit via a signal line.
- In the opposite direction, the control unit can also report faults to the DME control unit.
Diagnostic conditions
- Radiator fans activated > 5 Minute(s)
Possible fault causes
- Air intake Radiator covered (car cover)
- Radiator fan control module Faulty
Fault setting condition(s)
- Overtemperature in the Radiator fan control module
Fault effects
- 1.Threshold exceeded:
- rpm Radiator fans = 1800 1/min (Power loss at least)
- 2.Threshold exceeded:
- Radiator fans switched off