P2414
P2414Diagnosis information - Control unit DME (DFI)
Oxygen sensor in front of catalytic converter Bank 1 - sensor in air
NOTE:
Separated plug connection = open reference-air duct.
Damage to oxygen sensor.
- DO NOT use spray, grease, fluid or similar products on the oxygen sensor plug connections.
INFORMATION
- Do not interchange the oxygen sensor in front of the catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.
- The plugs themselves are coded and cannot be interchanged.
Diagnostic conditions
- Lambda control Active
- Driving > 10 Second(s), at:
- without Overrun phase(s)
- No fault entered for : Oxygen sensor(s) or Fuel/air mixture preparation
Possible fault causes
- Injection valve Mechanical fault / blocked (e.g. due to chip in the fuel rail)
- Oxygen sensor in front of catalytic converter Bank 1 not installed (only electrically connected)
- Oxygen sensor in front of catalytic converter Bank 1 Faulty