P2A03

P2A03

Diagnosis information - Control unit DME (DFI)

Oxygen sensor in front of catalytic converter Bank 2 , Electrical fault

NOTE:
Separated plug connection = open reference-air duct.
Damage to oxygen sensor.

- DO NOT use spray, grease, fluid or similar products on the oxygen sensor plug connections.

INFORMATION
- Do not interchange the oxygen sensor in front of the catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.
- The plugs themselves are coded and cannot be interchanged.

Diagnostic conditions
- Engine running > 30 Second(s) , at:
- Exhaust gas temperature > 100 °C (°F)
- Oxygen sensor in front of catalytic converter ready for operation
- without Overrun phase(s)

Possible fault causes
- Fault in area : Oxygen sensor in front of catalytic converter Bank 2

Fault setting condition(s)
- Temperature implausible (Oxygen sensor in front of catalytic converter)

Fault effects
- Since oxygen sensing is interrupted the moment a fault is detected, the DME (DFI) control unit stores this fault as information.
- Other faults have been entered
- The vehicle must be driven in the same driving cycle (without ignition reset) for this purpose.