Operation CHARM: Car repair manuals for everyone.

Radiator Fans Implausible Signal

P194600

Diagnosis information DME control unit

Radiator fans Implausible signal

DANGER:
High voltage:
Death or severe injuries due to high voltage or high current.


- De-energise the vehicle in accordance with the guidelines.
- Work must not be performed on parts carrying a high voltage.

Diagnostic conditions
The control unit must be active in order to test internal function sequences and diagnosable inputs/outputs.
In the event of a fault, check whether the fault is permanently >present<. To perform the check, erase the fault memory, meet the diagnostic conditions and read out the fault memory again.
- Ignition on
- Diagnosis only active when DME control unit has been flashed again or coded

Possible fault causes
- Implausible signal

Fault setting condition(s)
- Feedback of DMW control unit fan variants outside thresholds

NOTE
Diagnosis/Fault finding.
- Control unit variant unable to be reported back