Fault Conditions
P1671
Limp-home Relay, Short To B+
NOTE: The relay/electrical circuit that activates the throttle's limp-home function is faulty.
Fault symptoms
- CHECK ENGINE.
On-Board Diagnostics
Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
Enable criteria:
- Engine running. Main relay voltage exceeding 10 V. Output is active.
Fault criteria:
- Output voltage exceeding 2 V for more than 1 s.
Dependents:
- None.
System reaction to a fault:
- None.
OK report:
- Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
Fault handling: (For more information refer to "Fault diagnosis, general". Fault Handling III, Other Emission-Related Components and Function)
- Type III.
Diagnostic help
Fault diagnosis concerns electrical faults in connecting cables or in the relay.
Check the wiring
Jiggle the leads and in-line connectors at various points and in different directions to detect any intermittent breaks or short circuits in the wiring. Observe the multimeter, test lamp or diagnostic tool while doing this.