B1009
B1009
Control Module. Internal Fault
Fault symptoms
- The LED on the control button unit shows a red light.
On-Board Diagnosis
Type of diagnosis:
- Once every driving cycle
Enabling criteria:
- Ignition ON.
Fault criteria:
- Internal fault in control module (EEPROM).
Diagnostic help
The present fault code is erased directly the fault ceases. The historical fault codes are erased after 50 fault free driving cycles.
Fault Diagnosis Procedure (2005;2006;2007;2008;2009;2010)