B1746
B1746
Outdoor Temperature Sensor. Open Circuit / Short to B+
Fault symptoms
The external temperature function is faulty.
Type of diagnosis
Continuous
Enable criteria
Ignition ON
Fault criteria
In case of an open circuit, the resistance of the circuit is greater than 415 kohm.
In case of a short circuit to ground, the resistance of the circuit is less than 100 ohm.
Diagnostic help
The value for ambient temperature (unfiltered/filtered) can be read with the diagnostic tool.
The displayed ambient temperature can be adjusted with the diagnostic tool ± 5°C.
Checking the wiring harness
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Check switches, connectors and crimp connections for oxidation, withdrawn pins and pin clamping force.
Fault diagnosis procedure is not available.