Operation CHARM: Car repair manuals for everyone.

B1480




DTC B1480

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions) provides an overview of each diagnostic category.

DTC Descriptor
DTC B1480 00
- Battery Rundown Protection Circuit

Diagnostic Fault Information





Circuit/System Description

The body control module (BCM) supplies battery positive voltage to the reading lamps and both visor vanity mirror lamps. In the event that any of these lamps were to remain illuminated for more than 20 minutes with the ignition switch in the OFF position, the BCM will deactivate the inadvertent power courtesy lamps supply voltage circuit to prevent a total battery discharge condition

Conditions for Running the DTC

The battery voltage must be between 9-16 volts.

Conditions for Setting the DTC

* The TBC 4 fuse battery supply circuit to the BCM is open or shorted to ground.
* The inadvertent power supply voltage circuit to the reading and vanity mirror lamps is shorted to ground.

Action Taken When the DTC Sets

The reading and vanity mirror lamps will be inoperative.

Conditions for Clearing the DTC

* This DTC will clear on current status after the condition for setting the fault is corrected.
* A history DTC will clear after 100 consecutive ignition cycles without a fault present.

Reference Information
Schematic Reference

Interior Lights Schematics (Interior Lights Schematics)
Connector End View Reference

Component Connector End Views (Connector Views)
Description and Operation

Interior Lighting Systems Description and Operation (Interior Lighting Systems Description and Operation)
Electrical Information Reference

* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing for Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)

Scan Tool Reference

Control Module References (Programming and Relearning) for scan tool information

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector X3 at the BCM.
2. Verify that a test lamp illuminates between the B+ circuit terminal B17 and ground.

If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, and the B+ circuit fuse is open, test the inadvertent power supply circuit terminal B18 for a short to ground.

3. If the circuits test normal, replace the BCM.

Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.

Control Module References (Programming and Relearning) for BCM replacement, programming, and setup