Air Conditioning Cycling Switch Replacement
Air Conditioning Cycling Switch Replacement
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
1. Disconnect the A/C low pressure switch electrical connector.
2. Remove the A/C low pressure switch (2) from the accumulator (1).
3. Remove and discard the O-ring seal from the A/C low pressure switch port on the accumulator.
Installation Procedure
1. Install the new O-ring seal. Refer to O-Ring Replacement (O-Ring Replacement).
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the A/C low pressure switch (2) to the accumulator (1). Tighten the A/C low pressure switch to 4.8 Nm (42 in. lbs.)
3. Connect the A/C low pressure switch electrical connector.
4. Leak test the fittings of the components using the J 39400-A .