Operation CHARM: Car repair manuals for everyone.

Bootlid Lock Microswitch (622)



Bootlid Lock Microswitch (622)

Location

Bootlid lock microswitch (622)

Main task

Used to open the bootlid from the outside.

Type






The switch contains a single pole breaker. When the handle is not touched the breaker is open. When the handle is pushed in the switch makes.

Connect






The control module input is digital. A voltage above 2V is interpreted as an open circuit while lower than 2V is interpreted as closed.

Diagram 4D






Diagram 5D






Diagram CV