B3150
DTC B3140 or B3150
Diagnostic Instructions
- Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
- Review Strategy Based Diagnosis for an overview of the diagnostic approach.
- Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptors
DTC B3140 00
Driver Unlock Switch Circuit
DTC B3150 00
Driver Lock Switch Circuit
Diagnostic Fault Information
Circuit/System Description
The body control module (BCM) monitors the voltage level of the door lock and door unlock signal circuits. When the central door lock switch is in the open position, the voltage level in the signal circuit will be near 0 V. When the central door lock switch is pressed to the lock or unlock position, a signal will be sent to the BCM requesting a lock or unlock command.
Conditions for Running the DTC
The system voltage is 9-16 V.
Conditions for Setting the DTC
B3140 00
The BCM detects short to ground in the unlock signal circuit for greater than 60 seconds.
B3150 00
The BCM detects a short to ground in the lock signal circuit for greater than 60 seconds.
Action Taken When the DTC Sets
The door lock switch will malfunction.
Conditions for Clearing the DTC
- The DTC will be current for as long as the fault is present.
- When the fault is no longer present, the DTC will be a history DTC.
- A history DTC will clear after 50 ignition cycles.
Reference Information
Schematic Reference
Door Lock/Indicator Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Power Door Locks Description and Operation
Electrical Information Reference
- Circuit Testing
- Connector Repairs
- Testing for Intermittent Conditions and Poor Connections
- Wiring Repairs
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Ignition ON, observe the scan tool BCM Central Door Lock Switch on Console parameter. The reading should be Inactive and change to Lock and Unlock when pushing the appropriate switch.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the A20 radio/HVAC control.
2. Ignition ON, verify the scan tool Central Door Lock Switch on Center Console parameter is Inactive.
3. If the value is Lock, test the signal circuit terminal 12 for a short to ground. If the circuit tests normal, replace the K9 BCM.
4. If the value is Unlock, test the signal circuit terminal 13 for a short to ground. If the circuit tests normal, replace the K9 BCM.
5. If all circuits test normal, replace the A20 radio/HVAC control.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for BCM and HVAC control replacement, setup and programming