P0141

Schematic:




The heated oxygen (HO2S) bank 1 sensor 2 is threaded into the from exhaust pipe directly behind the cylinder 1, 3, 5 pre-converter (cylinders 1, 3, 5 are closest to front of dash). The sensor is used by the ECM to determine the oxygen storage capability of the pre-converter, fuel trim biasing (time held lean or rich) and certain techniques used to diagnose DTCs associated with the pre-catalyst oxygen sensor. The sensor is equipped with a beater to provide additional heat to speed up sensor activation time. The ECM calculates the efficiency of the sensor heating element by calculating the internal sensor (NOT HEATER) resistance based on actual current and signal voltage measurements on circuit 1668 after the engine has been running a certain length of time. As temperature increases, the sensor internal resistance will decrease. The ECM compares modeled sensor resistance values to the measured values based on the calculated sensor temperature (exhaust gas temperature). If the heater is working properly, the internal sensor resistance will decrease at a certain rate based on the exhaust gas temperature. If the heater is working properly, the internal sensor resistance will decrease at a certain rate based on the exhaust gas temperature. If the resistance takes too long to decrease or is too high after a certain amount of engine run time, the heater is assumed to be heating insufficiently. DTC P0141 will set if the calculated internal sensor resistance is too high after a certain length of engine run time indicating an inefficient heating element.

DTC PARAMETERS
DTC P0141 will set if the HO2S bank 1 sensor 2 calculated sensor resistance (based on the actual signal voltage and actual signal current) is greater than 63 ohms when:
^ Engine run time is greater than 10 seconds
^ Exhaust pipe moisture has evaporated (calculated engine run time between 0 and 200 seconds)
^ Calculated converter temperature is between 350 and 282°C (662 and 1085°F)
^ Main relay voltage is between 10.5 and 18 volts
^ No HO2S bank 1 sensor 2 heater circuit DTCs have been set

DTC P0141 diagnostic runs continuously once the above conditions have been met.

P0141 is a type B DTC.

DIAGNOSTIC AIDS
If DTC P0140 is also set, diagnose that DTC first. An open in the sensor signal or sensor return may set this DTC.

Make sure no corrosion is present in the HO2S bank 1 sensor 2 harness connector and that all terminals (heater AND signal) are contacting correctly. If OK, replace the HO2S bank 1 sensor 2.

Heater element resistance 7.0-20.2 ohms