P0157
Diagnostic Chart:
Schematic:
The heated oxygen (HO2S) bank 2 sensor 2 is threaded into the front exhaust pipe directly behind the cylinder 2, 4, 6 pre-converter (cylinders 2, 4, 6 are closest to radiator). The sensor is used by the ECM to determine the oxygen storage capability of the pre-converter, fuel trim biasing (time held lean or rich) and certain techniques used to diagnose DTCs associated with the pre-catalyst oxygen sensor. The sensor is an electrical source that responds to oxygen content Out of the pre-converter. When the sensor reaches approximately 316°C (600°F) it is fully functional and produces a voltage based on the difference in oxygen between the atmosphere and exhaust gas. The ECM sends a 450 mV bias voltage on the signal line, which is pulled up through high resistance. When the HO2S bank 2 sensor 2 is cold, it produces no voltage and has extremely high internal resistance. The internal resistance of the sensor is much greater than the resistance of the bias pull-up resistor. However, when the sensor heats up, it produces voltage that overrides the bias voltage. Under normal conditions, low sensor voltage means high oxygen content/lean air-fuel mixture and vice versa. Normal sensor readings will be around 500-800 mV under steady cruise. DTC P0157 will set if the HO2S bank 2 sensor 2 is too low for a certain length of time; OR if the HO2S bank 2 sensor 2 does not go over 600 mV at least once within a certain amount of time when the HO2S bank 2 sensor 2 is being used for fuel trim biasing or catalytic converter monitoring.
DTC PARAMETERS
DTC P0157 will set if HO2S bank 2 sensor 2 signal is less than 40 mV when:
^ Condition exists for longer than 11 minutes and 20 seconds
^ Exhaust pipe moisture has evaporated (calculated engine run time between 0 and 200 seconds), then engine must run for longer than 80 seconds
^ HO2S bank 2 sensor 2 loop status is closed
^ Fuel tank is not empty (low fuel telltale is not On)
^ MAF is greater than 9.72 g/s
^ Calculated exhaust gas temperature is less than 800°C (1472°F)
^ Main relay voltage is greater than 10.5 volts
^ No EVAP purge solenoid or EVAP flow during non-purge DTCs have been set
OR
HO2S bank 2 sensor 2 signal does not go over 600 mV at least once in 400 seconds when the ECM has one time invoked a rich condition when:
^ HO2S bank 2 sensor 2 loop status is closed
^ Engine airflow is greater than 9.72 g/s
^ ECM has determined that a rich or lean engine running condition is NOT present (long term fuel trim is OK)
^ EVAP leak diagnostics are not running
^ No CAM, EVAP purge solenoid, fuel trim, HO2S bank 2 sensor 2 heater or misfire DTCs have been set
DTC P0157 diagnostic runs continuously once the above conditions have been met.
P0157 is a type B DTC.
DIAGNOSTIC AIDS
To locate an intermittent problem, use Scan tool to monitor HO2S BANK 2 SENSOR 2 with ignition On and engine Off after the engine has cooled down. Wiggling wires while watching for a change from bias voltage (450 mV) may locate the area where a short to ground in the wiring may exist.
The Scan tool contains the special function BANK 2 SENSOR 2 OSCILLATION TEST. This test will force the ECM to introduce an oscillating air/fuel ratio, while it monitors the performance of the HO2S bank 2 sensor 2. DTC P0157 will reset if the fault is currently present.
NOTE: A short to ground on the HO2S bank 2 sensor 2 signal low circuit 1671 will NOT affect the sensor signal circuit.