23. End Play Measurement
END PLAY MEASUREMENT1. Assemble 8" Dial Indicator Extension Rod (1) and Dial Indicator Set J45200 (2) on to the end of fluid pump and set the dial indicator J45200.
2. Move the input shaft and measure end play. If end play is out of specifications, select another washer.