Air Door: Service and Repair
AIR INLET ASSEMBLY REPLACEMENTREMOVAL PROCEDURE
1. Remove the HVAC module.
2. Disconnect the electrical connector from the recirculation actuator.
3. Unclip the wire harness from the HVAC module end bracket.
4. Remove the end bracket screws from the air inlet assembly.
5. Remove the end bracket nuts from the blower case assembly.
6. Remove the end bracket from the blower case assembly.
7. Remove the recirculation actuator screws.
8. Remove the recirculation actuator.
9. Remove the air inlet assembly screws.
10. Remove the air inlet assembly.
INSTALLATION PROCEDURE
1. Install the air inlet assembly.
2. Install the air inlet assembly screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1 N.m (9 lb in).
3. Install the recirculation actuator.
4. Install the recirculation actuator screws.
Tighten the screws to 1 N.m (9 lb in).
5. Route the HVAC module harness through the end bracket bottom hole and install the bracket.
6. Install the end bracket screws.
Tighten the screws to 2 N.m (18 lb in).
7. Install the end bracket nuts.
Tighten the nuts to 2 N.m (18 lb in).
8. Clip the wire harness to the end bracket.
9. Install the electrical connector to the recirculation actuator.
10. Install the HVAC module.