Scan Tool Data Definitions
SCAN TOOL DATA DEFINITIONS
PCM - A/C Disengage Reason: The scan tool displays the last reason the A/C compressor was disengaged.
PCM - A/C Off For WOT : The scan tool displays Yes or No. Yes indicates that the PCM has disabled the A/C compressor because the TP sensor signal is at wide open throttle.
PCM - A/C Pressure Disable: The scan tool displays Yes or No. Yes indicates that the PCM has disabled the A/C compressor due to excessive refrigerant pressure.
PCM - A/C High Side Pressure : The scan tool displays -103 to +3119 kPa, -14 to +452 psi. This parameter represents the A/C refrigerant pressure sensor voltage signal converted to pressure.
PCM - A/C High Side Pressure : The scan tool displays 0.00-5.00 Volts. This parameter represents the A/C refrigerant pressure sensor signal.
PCM - A/C Relay Command : The scan tool displays On or Off. Represents the PCM commanded state of the A/C compressor clutch relay control circuit. The A/C compressor clutch should be engaged when Commanded A/C displays On.
PCM - A/C Relay Circuit History : The scan tool displays OK, Open, Short or Invalid State. This parameter indicates the state of the driver circuit for this device.
PCM - A/C Request Signal : The scan tool displays Yes or No. The PCM uses the A/C request signal in order to determine if A/C compressor operation is being requested by the HVAC Control Module.
HVAC - A/C Request: The scan tool displays Yes or No. This states that the A/C request is being made by the HVAC control module.
HVAC - Recirculation Dr. Position: This data indicates the actual door position.
HVAC - Recirculation Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Mode Dr. Position: This data indicates the actual door position.
HVAC - Mode Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Defrost Dr. Position: This data indicates the actual door position.
HVAC - Defrost Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Driver Temp Dr. Position: This data indicates the actual door position.
HVAC - Driver Temp Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Psgr. Temp Dr. Position: This data indicates the actual door position.
HVAC - Psgr. Temp Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Aux Mode Dr. Position: This data indicates the actual door position.
HVAC - Aux Mode Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Aux Temp Dr. Position: This data indicates the actual door position.
HVAC - Aux Temp Dr. Motor Command: This data indicates the value of the commanded door position.
HVAC - Evaporator Temp Sensor: The scan tool displays 0 to 255 counts.
HVAC - Evaporator Sensor: The scan tool displays -40 to +215°C (-40 to +420°F). The output of the A/C low side thermistor.
HVAC - Mode Status (Display Recirc/Vent/Mix-Blend/Floor/Bi-Level/Defrost): This data indicates the mode selection knob position.
HVAC - A/C LED: The scan tool displays on or off. This is the status of the LED.
HVAC - Rear Defrost LED: The scan tool displays on or off. This is the status of the LED.
HVAC - Driver Heated Seat Status: The scan tool displays Off/Low Heat/High Heat. This is the status of the heated seat switch.
HVAC - Passenger Heated Seat Status: The scan tool displays Off/Low Heat/High Heat. This is the status of the heated seat switch.
HVAC - Blower Motor Switch Position: The scan tool displays Off/On But Not High Blower/On and High Blower. This is the status of the Blower Motor switch Position.
HVAC - Aux. Blower Motor Speed Command: The scan tool displays 0 to 255 counts. This is the auxiliary blower motor commanded speed.
HVAC - Aux. Blower Motor Switch Position: The scan tool displays Aux/Off/1/2/3/4. This is the status of the Auxiliary Blower Motor switch Position.
HVAC - Aux. Blower Motor Speed: The scan tool displays 0 to 255 counts. This is the actual status of the Auxiliary Blower Motor speed.