Instrument Panel Cluster (IPC) - Replacement
INSTRUMENT PANEL CLUSTER (IPC) REPLACEMENT
REMOVAL PROCEDURE
1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 3 in Restraint Systems.
2. Place the steering column in the lowest position.
3. Remove the I/P cluster trim plate.
4. Remove the fasteners from the upper and the lower cluster. Pull rearward to remove the I/P cluster.
5. Disconnect the I/P cluster harness.
INSTALLATION PROCEDURE
1. Connect the I/P cluster harness.
2. Install the I/P cluster in the I/P housing. Install and tighten the fasteners.
NOTE: Refer to Fastener Note in Service Precautions.
Tighten the fasteners to 2 N.m (18 lb in).
3. Install the I/P cluster trim plate.
4. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 3.