Disassemble
Transfer Case Disassemble- Tools Required
- J 44873 Pinion Flange Holder and Remover
1. Remove the ventilation valve (408), hose (407) and clamps (406).
2. Remove the drain plug (403) and washer (404).
3. Remove the fill plug (401) and washer (402).
4. Remove the bolts (102) and cover (101).
5. Remove the seal (305) and O-ring (304).
6. Remove the locating pin (105).
7. Remove the input gear (214).
8. Remove the bearing (217) and 25 mm shim (216).
9. Mark or tag the shim (216) for assembly.
10. Secure the case in a vise with soft jaws.
11. Using a chisel, cut the locking tab on the locknut (210).
Notice: Refer to Fastener Notice in Cautions and Notices.
12. Install the J 44873 and bolts to the output yoke.
- Tighten the bolts to 48 Nm (35 ft. lbs.).
13. Loosen the locknut.
14. Remove the J 44873 and bolts.
15. Remove the nut (210), washer (209), sealing washer (303), O-ring (302), and output yoke (208). Note the washer (209) installed position.
16. Remove the output shaft (201) with bearing, collapsible spacer (204) and washers (215).
17. Remove the seal (301) and bearing (207).