Blower Motor Control Module Replacement
Blower Motor Control Module Replacement
Removal Procedure
1. Disconnect the electrical connector from the blower motor control module.
2. Remove the blower control module screws from the HVAC module.
3. Remove the blower motor control module from the HVAC module.
Installation Procedure
1. Install the blower motor control module to the HVAC module.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the blower motor control module screws to the HVAC module and tighten the screws to 1.5 Nm (13 lb in).
3. Connect the electrical connector to the blower motor control module.