Circuit 1637, 1629
CIRCUITs 1637 and 1629
Function:
This circuit provides the power and ground for the right passive restraint motor. When the motor moves the mouse to the A pillar, circuit 1629 is the power to the motor and circuit 1637 is the ground. When the mouse moves to the B pillar, 1637 is power and 1629 is ground.
CIRCUIT 1629
Location:
Connects the passive restraint control module connector cavity E to right motor connector cavity B.
Type:
Brown 18 gage wire
CIRCUIT 1637
Location:
Connects the passive restraint control module connector cavity H to left motor connector cavity C.
Type:
Gray 18 gage wire