Circuit 3A/139
CIRCUIT 3A/139
Function:
This circuit supplies battery voltage to the I/P junction block. This voltage powers the turn lamps.
Repairs:
Check for OPENS/SHORTS
Repair as needed.
If this component is good, go to the next item indicated on the Symptom Chart.
CIRCUIT 3A
Location:
Connects 3 connector splice pack to the I/P junction block connector cavity D8.
Type:
Pink 14 gage wire
Repairs:
Check for OPENS/SHORTS
Repair as needed.
If this component is good, go to the next item indicated on the Symptom Chart.
CIRCUIT 139
Location:
Connects I/P junction block connector cavity A4 to turn/hazard switch connector cavity C.
Type:
Pink/Black 20 gage wire
Repairs:
Check for OPENS/SHORTS
Repair as needed.
If this component is good, go to the next item indicated on the Symptom Chart.