Neutral Safety Switch: Adjustments
Neutral Safety Switch Adjustments:
ADJUSTMENT
1. Loosen mounting nuts.
2. Place transaxle in D (Drive). Use ohmmeter or continuity tester to check for continuity across terminals on selector switch if no continuity is present rotate switch to achieve continuity.
3. Tighten switch to case bolts, After switch to case bolts have been tightened check continuity.
Torque: 14 Nm (124 in lbs)