Circuit 663
LOCATION:
Connects turn/hazard switch connector cavity F to I/P cluster connector cavity 0.
TYPE:
Light Blue/Black 22 gage wire
FUNCTION:
This circuit supplies battery voltage to the I/P cluster left turn signal from the turn/hazard switch.
REPAIRS:
Check for OPENS/SHORTS
Repair as needed.
If this component is good, go to the next item indicated on the Symptom Chart.