Circuit 640 and 1936
CIRCUIT 640 and 1936
Function:
These circuits supply power to the passive restraint control module at all times.
CIRCUIT 640
Location:
Connects the P REST Fuse through I/P junction block connector cavity C6 to the passive restraint control module connector cavity C.
Type:
Orange 18 gage wire
Function:
Battery voltage should be present at all times.
Repair:
Check for OPENS/SHORTS.
CIRCUIT 1936
Location:
Connects underhood junction block connector cavity A to I/P junction block connector cavity F6.
Type:
Red/White 14 gage wire
Repair:
Check for OPENS/SHORTS.