Fuse Circuits Testing
R HDLP FuseLocation: Underhood junction block
Type: 10A Minifuse
Feeds: Circuit 140A and 140B
if the following system is operating normally, the fuse is most likely good:
^ Right high beam
^ Right low beam
If the fuse is blown, determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good, go to the next item indicated on the Complaint-Condition Chart.
HAZARD Fuse
Location: Underhood junction block
Type: 10A Minifuse
Feeds: Circuit 1040
If the following system is operating normally, the fuse is most likely good:
^ Hazard lamps
If the fuse is blown, determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good, go to the next item indicated on the Complaint-Condition Chart.
IGN3 Fuse
Location: Underhood junction block
Type: 30A Maxifuse
Feeds: Circuit 102A
If the following system is operating normally, the fuse is most likely good:
^ Generator
^ Cruise control
^ HVAC blower motor
If the fuse is blown determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good, go to the next item indicated on the Complaint-Condition Chart.
IGN4 Fuse
Location: Underhood junction block
Type: 30A Maxifuse
Feeds: Circuit 202
If the following system is operating normally the fuse is most likely good:
^ I/P cluster
^ Windshield wipers
^ Radio
^ Turn signals
If the fuse is blown determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good go to the next item indicated on the Complaint-Condition Chart.
IGN3 Fuse
Location: Instrument panel junction block
Type: 7.5A Minifuse
Feeds: Circuit 641 and RR DEFOG relay coil
If the following system is operating normally, the fuse is most likely good:
^ Generator
^ Power window
^ A/C
^ DRL
If the fuse is blown determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good, go to the next item indicated on the Complaint-Condition Chart.
IGN1 Fuse
Location: Instrument panel junction block
Type: 10A Minifuse
Feeds: Circuit 39
If the following system is operating normally, the fuse is most likely good:
^ I/P cluster
^ Transaxle shift program switch
^ Power door locks
If the fuse is blown, determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good go to the next item indicated on the Complaint-Condition Chart.
L HDLP Fuse
Location: Underhood junction block
Type: 10A Minifuse
Feeds: Circuits 40A and 40B
If the following system is operating normally, the fuse is most likely good:
^ Left high beam
^ Left low beam
If the fuse is blown, determine the cause of the blown fuse and repair.
Replace fuse as needed.
If this component is good go to the next item indicated on the Complaint-Condition Chart.