Manual Transmission
Back Up Light Switch (Manual Transaxle): Removal:
REMOVAL
1. Remove air induction system.
Back Up Light Switch (Manual Transaxle): Installation:
2. Disconnect electrical connector.
3. Remove switch.
INSTALLATION
1. Apply sealant with Teflon(R) P/N 21485278 or equivalent on threads before installing.
2. Install switch
Torque: 38 N^m (28 ft-lbs)
3. Connect electrical connector to switch.
Back Up Light Switch (Manual Transaxle): Installation:
4. Install air induction system.