Removal
1. Remove air induction system.
2. Disconnect electrical connectors from selector switch.
3. Disconnect shifter cable from control lever.
4. Place control lever in the full clockwise position.
NOTICE: If manual shift shaft is rotated excessively, internal damage to the transaxle range switch may occur.
5. Prevent the manual shift shaft from rotating by holding control lever while removing retaining nut from manual shift shaft. Remove control lever.
6. Remove two switch-to-transaxle case bolts and remove switch.