Compressor at Minimum Displacement
Compressor At Minimum Displacement:
KEY: 1. INCREASED SUCTION PRESSURE FOR A RELATIVELY LOW DISCHARGE PRESSURE.
2. HIGH OUTLET TEMPERATURES
THEN: Compressor may be at minimum displacement.
^ This condition will be most noticeable at high ambients.
^ Confirm charge level before replacing compressor.
^ After repair return to diagnostic flow chart.