Blower Motor Switch
REMOVAL1. Remove control head.
2. Remove face plate.
3. Remove fan switch lever by prying straight off with a small flat blade screwdriver.
4. Using a flat blade screw driver lift retaining barb on top side of switch assembly and pull switch out of control head.
INSTALLATION
1. Press fan switch into control head from rear until retaining barb is seated.
2. Press fan switch lever onto fan switch until seated.
3. Install control head face plate.
4. Install control head.