Operation CHARM: Car repair manuals for everyone.

Heated Oxygen Sensor 1, Bank 1 and Bank 2

TOOLS REQUIRED
^ J39194C O2 Sensor Wrench

REMOVAL




1. Disconnect oxygen sensor electrical connector.
2. Remove oxygen sensor using O2 Sensor Wrench J39194C.

INSTALLATION




1. Apply anti-seize material to threads of new oxygen sensor.
2. Install oxygen sensor using 02 Sensor Wrench J39194C.

Torque:
Oxygen Sensors (Exhaust Manifold): 50 N.m (37 ft-lbs)

3. Connect oxygen sensor electrical connector.