82. Torque Converter Housing Installation
Torque Converter Housing Installation1. Remove the case fluid passage seal (89).
2. Install a NEW case fluid passage seal (89) into the transmission case assembly.
3. Apply RTV sealant to the torque converter housing assembly.
4. Install the torque converter housing assembly to the transmission case assembly.
Important: Use LOCTITE Tm 242 thread sealer on ALL bolt threads.
5. Install the 11 - M8 x 1.25 x 30 mm bolts (1) and hand tighten.
6. Install the 2 - M8 x 1.25 x 30 mm bolt/studs (2) and hand tighten.
7. Install the 2 - M8 x 1.25 x 35 mm bolts (3) and hand tighten.
8. Install the 1 - M8 x 1.25 x 45 mm bolt (4) and hand tighten.
9. Install the 1 - M8 x 1.25 x 30 mm TORX(R) 40 bolt (5) and hand tighten.
Notice: Refer to Fastener Notice in Service Precautions.
10. Tighten the 15 torque converter housing bolts in sequence.
^ Tighten the torque converter housing bolts to 23.5 - 35.3 Nm (17.33 - 26.00 ft. lbs.).