Air Cleaner Housing: Service and Repair
AIR CLEANER ASSEMBLY REPLACEMENTREMOVAL PROCEDURE
1. Remove the air cleaner outlet duct.
2. Remove the air cleaner assembly attachment fasteners.
3. Remove the air cleaner.
INSTALLATION PROCEDURE
1. Position the air cleaner assembly.
IMPORTANT: Verify full engagement of the inlet onto the resonator neck.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the air cleaner assembly attachment bolts.
Tighten the bolts to 10 N.m (89 lb in).
3. Connect the air cleaner resonator to the air cleaner assembly.
Tighten the air cleaner outlet duct clamps to 5 N.m (44 lb in).