Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the refrigerant pressure sensor electrical connector.
2. Using a back-up wrench to support the refrigerant line, remove the refrigerant pressure sensor.
INSTALLATION PROCEDURE
1. Lubricate the pressure port O-ring with mineral oil.
IMPORTANT: Do not use PAG oil.
2. Hand start the refrigerant pressure sensor onto the pressure port.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Using a back-up wrench to support the refrigerant line, tighten the refrigerant pressure sensor.
Tighten the refrigerant pressure sensor to 7 N.m (62 lb in).
4. Connect the refrigerant pressure sensor electrical connector.