Typical Parasitic Loads

Typical parasitic load for this vehicle is 10-15 mA. If the vehicle does not have one of the following components, then subtract the parasitic load of the component for typical parasitic load of the vehicle (10-15 mA) to determine the parasitic load range for the vehicle being tested.






Important: During CD changer initialization, parasitic current draw will fluctuate between 3 mA to 1 A. The initialization period lasts up to a maximum of 90 seconds. After initialization, the CD changer parasitic current draw will stabilize at approximately 3mA.

If the CD changer door is open and the light is illuminated, the parasitic current draw will be approximately 65 mA. The light will remain ON for 2 minutes. After the light goes out, the CD changer parasitic current draw will stabilize at approximately 3 mA.