Blower Motor Resistor: Service and Repair
Blower Motor Resistor Assembly Replacement
Removal Procedure
1. Remove the instrument panel (I/P) compartment.
1. Remove the 4 bolts (1).
2. Disconnect the wiring harness plug.
2. Remove the series resistor (2) upwards from air distributor housing.
Important: Access to the wiring harness plug for release is difficult.
3. Disconnect the resistor and fan motor wiring harness plugs.
Disconnect and remove the 3 wiring harness plugs (1).
4. Remove the resistor.
Installation Procedure
1. Install the resistor.
2. Connect the resistor and fan motor wiring harness plugs.
Connect the 3 wiring harness plugs.
Notice: Refer to Fastener Notice (Fastener Notice) .
3. Install the I/P compartment.
Connect the wiring harness plug.
Tighten the 4 bolts to 4 N.m (35 lb in).