Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Replacement
Removal Procedure
1. Remove the intake manifold cover. Refer to Intake Manifold Cover Replacement (Service and Repair).
2. Disconnect the engine wiring harness electrical connector (1) from the exhaust camshaft position (CMP) actuator solenoid valve (4), if required.
3. Disconnect the engine wiring harness electrical connector (2) from the intake CMP actuator solenoid valve (3), if required.
4. Remove the exhaust (1) CMP actuator solenoid valve bolt and valve, if required.
5. Remove the intake (2) CMP actuator solenoid valve bolt and valve, if required.
6. Inspect the solenoid valve O-ring seals for damage, replace as necessary.
Installation Procedure
1. Lubricate the solenoid valve O-ring seals with clean engine oil.
Notice: Refer to Fastener Notice (Fastener Notice).
2. Install the intake (2) CMP actuator solenoid valve and bolt, if required.
Tighten the bolt to 10 N.m (89 lb in).
3. Install the exhaust (1) CMP actuator solenoid valve and bolt, if required.
Tighten the bolt to 10 N.m (89 lb in).
4. Connect the engine wiring harness electrical connector (2) to the intake CMP actuator solenoid valve (3), if required.
5. Connect the engine wiring harness electrical connector (1) to the exhaust CMP actuator solenoid valve (4), if required.
6. Install the intake manifold cover. Refer to Intake Manifold Cover Replacement (Service and Repair).