Blower Motor: Service and Repair
Blower Motor Replacement
Removal Procedure
1. Remove the instrument panel (I/P) compartment.
1. Remove the 4 bolts (1).
2. Disconnect the wiring harness plug.
2. Remove the passenger side lower footwell trim.
Remove the bolt (3).
3. Remove the air duct.
Remove the body-bound rivet (2).
4. Remove the blower motor (2).
1. Disconnect the 2 wiring harness plugs (1) from series resistor.
2. Remove the 5 bolts.
Installation Procedure
Caution: Refer to Fastener Caution (Fastener Caution).
1. Install the blower motor.
1. Connect the clip.
Tighten the 5 bolts to 6 Nm (63 lb in).
2. Connect the 2 wiring harness plugs.
2. Install the air duct.
Install the body-bound rivet.
3. Install the lower right footwell trim.
Tighten the bolt - pivot and lock.
4. Install the I/P compartment.
Connect the wiring harness plug.
Tighten the 4 bolts to 4 Nm (35 lb in).