Procedures
Range Selector Lever Cable Inspection
Special Tools
KM-962-A /KM-962-10 Tester
Removal Procedure
1. Remove the battery.
* Disconnect the negative cable (2) from the battery.
Remove the nut.
* Disconnect the positive cable (3) from the battery.
Remove the nut.
* Remove the bracket (1).
Remove the bolt (4).
* Remove the battery.
2. Remove the battery support.
* Release the cable tie.
* Remove the 3 bolts (1).
3. Connect KM-962-A (3) to the wiring harness plug of the selector lever position switch
* Disconnect the wiring harness plug of the selector lever position switch (1).
* Open the locking shackle.
4. Connect KM-962-A with KM-962-A KM-962-10 (2) to the battery.
5. Inspect the setting of the selector lever position switch.
Note: The light diodes corresponding to the markings on the insert module (1) must flash for each individual gear.
* Shift through all the gears one after the other.
* If the setting is incorrect:
- Adjust the selector cable. Refer to Range Selector Lever Cable Adjustment (Adjustments).
- Adjust the selector lever position switch. Refer to Transmission Range Switch Adjustment (Adjustments).
- Inspect the electrical function of the selector lever position switch.
See test instructions.
Installation Procedure
1. Connect the selector lever position switch wiring harness plug.
* Disconnect KM-962-A from the selector lever position switch wiring harness plug.
* Disconnect KM-962-A from KM-962-10.
* Disconnect KM-962-A from the battery.
* Lock the wiring harness plug.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the battery support.
Fasten the cable tie.
Tighten 3 bolts 10 Nm (89 lb in).
3. Install the battery.
* Install the bracket (1).
* Tighten the bolt (4).
Tighten bolt 15 Nm (11 lb ft).
* Connect the positive cable (3) to the battery.
* Connect the negative cable (2) to the battery.
4. For programming procedures, refer to Control Module References (Programming and Relearning).