P0A4C
DTC P0A4C
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
DTC Descriptor
DTC P0A4C
- Starter/Generator Position Sensor Performance
Circuit/System Description
The starter/generator control module (SGCM) monitors the motor generator unit (MGU) angle position sensor circuit. to detect a fault in the angle data.
Conditions for Running the DTC
The engine is running.
Conditions for Setting the DTC
(Data error) R/D IC angle data does not match with micro computer angle data. Self check fault when initial sequence (initialization error).
Action Taken When the DTC Sets
Stop PWM (MGU shutdown)
Conditions for Clearing the DTC
Clears 30 seconds after cycle wakeup signal.
Diagnostic Aids
Possible electrical failure at RD circuit
Reference Information
Schematic Reference
Hybrid Controls Schematics (Electrical Diagrams)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Starter/Generator Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Testing
1. Disconnect the MGU X2 and the SGCM X2 connectors. Refer to Generator with Starter Replacement (Service and Repair) and Generator Control Module Replacement (Generator Control Module Replacement).
2. Test the circuits in the SGCM to MGU Terminal Reference Table as indicated below. Also test these circuits for short to ground.
• If any of the circuits are not within specification, repair the open/high resistance or short to ground.
3. Reconnect MGU connector X2.
4. Test the circuits in the MGU to SGCM Specification Table to ground as indicated below.
• If all circuits test normal, replace the MGU.
5. Reconnect the MGU X2 connector and disconnect the SGCM X2 connector. Refer to Generator with Starter Replacement (Service and Repair) and Generator Control Module Replacement (Generator Control Module Replacement).
6. Test the circuits in the SGCM to MGU Specification Table as indicated below.
• If any of the circuits are not within the specified range, replace the SGCM.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Generator with Starter Replacement (Service and Repair) for MGU replacement
* Control Module References (Programming and Relearning) for SGCM replacement, setup, and programming